Skip to main content
Biamp Cornerstone

Workplace Tools desktop app - Certificate is expired or not yet valid

Referencing an error while assigning devices, and a possible fix.

 

Seeing the error

This error may come up when assigning devices to an established location.  This error will be at the bottom of the page.

clipboard_ef8c00d8219f51f3d05cf4fb5d41347f6.png

 

 

Deciphering the error

The key to understanding the root cause of the error in this case is to note the current date/time as it was reported in the error.  In the screenshot provided the date/time is clearly inaccurate.

clipboard_e90b0bdc21f28b06765964d465478d4dc.png

In this screenshot the DSP in question has its date and time very far in the past, so far in fact that the NTP server was not syncing its clock anymore

 

 

Resolving the error

The issue is simply to update or correct the time on the device in question.  For a Tesira DSP this is a simple task in device maintenance window of the Tesira software

clipboard_e11d3635d1add5146cb2603e1ea2684ca.png

A user can from this window:

  • Sync the Tesira DSP to your PC clock, thus resolving the issue.
  • Ensure that the NTP that the Tsira DSP is pointed to is the correct one.
  • Manually assign a current date and time to the unit.

Any of the three options will resolve the errors in this case.

 