IR Sequence - Power on command
This sequence is always executed when the control system is off and any source key is pressed.
Normally you do not need to assign this sequence to any buttons, due to the fact that when you press a key with a source sequence on, the control system will automatically execute the power on sequence before executing the source sequence.
The advantage of this is that only the first time you press a source key (and the device has been turned off with the off sequence) the power on sequence will be executed.
Item |
Description |
The time between commands... |
Defines the time between sending the first command and the second command. If the second command are not in use, this time is discharged. |
The warm up time... |
The time from sending the last command in this sequence until the device is ready to change source. |
The time for the device when ready... |
The time from sending the last command in this sequence until the device is ready to power off again. |
The sequence has the following function:
When key is pressed:
- The LED on the button start flashing.
- First power on command is sent.
- Wait "Time between commands..." (if a second command is available).
- Second power on command is sent. (If available).
- Wait "The warm up time...".
- The LED stop flashing.
When key is released again:
- Nothing.