Skip to main content
Chat with Biamp tech support
Biamp Cornerstone

Getting started with Dynasound

This article describes how to identify the hardware components of a Dynasound sound masking system and how to connect to a Dynasound system using Biamp's Privacy Manager software. 

Requirements

To connect to Dynasound hardware, you will need the following:

  • Windows 7, 8, or 10 PC with an Ethernet port
  • An Ethernet cable that can be used to connect to the hardware itself
    • A crossover cable will be needed to connect directly
    • A straight-through cable can be used when going through a switch
  • A downloaded copy of Biamp's Privacy Manager software. This software is free to download and use.

CobraNet or 70V

The Privacy Manager may connect to devices existing in either a Cobranet or 70V system, or a blend of these two system types. The DS3002/DS3008 may be configured in the Privacy Manager software regardless of which system type is in use. The table below contains configuration considerations to help identify and work with each system type.

CobraNet 70V
  • DS3002/DS3008 unit(s) will be plugged into a network switch.
  • DS8000 units are dispersed throughout the building.
  • The network switch feeds CobraNet audio from DS3002/DS3008 units to DS8000 units.
  • The network switch handling CobraNet traffic should be isolated from the greater building network.
  • DS3002/DS3008 unit(s) may not be plugged into a network switch.
  • DS3002/DS3008's line level outputs will be connected to an amplifier.
    • DynasoundPro DSLG22 amplifier may be used.
    • Third-party amplifiers may also be used.
  • The amplifier will feed the sound masking signal to the loudspeaker(s).
  • Any amplifiers, attenuators, or other analog equipment in the system will not be discoverable in the Privacy Manager software, as they do not interact with the network.

Identifying Dynasound hardware

The table below provides information to help identify and utilize the hardware that may be found in a Dynasound system.

In 70V systems, only the DS3002/DS3008 will be discoverable in the Privacy Manager software.

In Cobranet systems, DS3002/DS3008, DS8000, and DSTS10POE devices may all be discovered by or interact with the Privacy Manager software.
 

Hardware Image Overview

DS3002

DS3008

DS3008_front-2-300x73.jpg
  • DS3002 and DS3008 units are both intended to be installed in a rack.
  • Both models act as the main sound masking source in a Dynasound system.
  • DS3002 units have 2 line-level inputs.
  • DS3008 units have 8 line-level inputs.
  • Both models have 8 line-level outputs.
  • Both models ship from the factory set to a static IP address. 
  • Both models have power supplies with the following specifications: barrel plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm center positive.
DS8000 DS8000new-2-242x300.jpg
  • DS8000 units are intended to be installed throughout a site and connected to the CobraNet network.
  • DS8000 units receive CobraNet audio from DS3002/DS3008 units via the network.
  • Each DS8000 unit can feed its received audio to up to 8 loudspeakers independently.
  • DS8000 units ship from the factory set to a static subnet. 
  • DS8000 units are powered via PoE using DSPoE24 network switch.
DSTS10POE

DST10POE-1-300x189.jpg

  • The DSTS10POE is a 10" touchscreen panel.
  • Allows for control of Dynasound devices via the CobraNet network, such as:
    • User adjustments
    • Sound masking level scheduling
    • Contact closure shutoff
  • Ships from the factory configured with Privacy Manager software.
  • Ships from the factory set statically to IP address 192.168.100.4.
  • Requires power from included power supply.

DSLG22
(70V only)

DSLG22.png
  • The DSLG22 is a sound masking amplifier.
  • The DSLG22 is suited for traditional 70V systems, as well as smaller installations.
  • Flexible IntelliDrive feature permits delivery of 2 x 100W at 70V or low impedance (2, 3, or 8 ohms) on any channel.
  • This device is not needed in CobraNet-based Dynasound systems.
DSRMP-8
(70V only)

DSRMP_front-2-300x57.jpg

  • The DSRMP-8 features 8 attenuator channels that can be used for attenuating sound masking signal only.
  • Each attenuator channel can be set to one of eleven possible attenuation levels (0-10), with 1.5 dBA increments between each.
  • Each attenuator channel is rated at 100W.
  • This device can be used in 70V-only systems as well as hybrid CobraNet and 70V systems. It cannot be used in CobraNet-only systems.

Dynasound IP scheme

Dynasound devices are configured in the factory with static IP addresses prior to shipping. All devices will be in the 192.168.100.xxx Class C subnet. Dynasound devices do not support DHCP. 

The table below indicates the respective IP address assignment for each Dynasound device model.

Device model IP address configuration

DSTS10POE

192.168.100.4

Note: this device is not discoverable in Privacy Manager software, but will show up on network scans.

DS3002/3008 192.168.100.5 
DS8000
  • IP addresses will begin at 192.168.100.6 and increment up to 192.168.100.250
  • If the quantity of units provided for by the above range is exceeded, IP addressing will then begin again at 192.168.101.6 and continue to increment

Connecting to a Dynasound system

When connecting to a Dynasound system via Privacy Manager, it is first necessary to configure the network of the computer running the software:

  1. Connect the computer to the CobraNet network.
    • The simplest way to do this is to connect an Ethernet cable from the computer to the CobraNet network switch.
  2. Configure the IP address of the computer to be in the same range as the Dynasound equipment.
    • Make sure it is not the same IP address as a device already in the system.
    • Regardless of how many devices are in the system, 192.168.100.3 should be available for the computer to use.

Once the computer has been configured for the CobraNet network, follow the steps below to connect to the Dynasound devices living on that network:

PMopen.png

PMSysSetup.png

PMDiscoveredpng.png

  1. Launch the Privacy Manager Software.
  2. Click on the Menu button.
  3. Click on System -> System Setup.
  4. Set the Starting IP to an IP address that should be present on the network given what is known about the devices in the system. The IP address 192.168.100.5 is a good Starting IP in most systems.
  5. Set the Ending IP to a high enough IP address to ensure that all devices will be included between the Starting IP and Ending IP. 

    It should be noted that the Privacy Manager software will manually search for devices at every IP address in the provided range. This means that very large systems may take additional time for all devices to be discovered.  Depending on the size of the system and the specific reason for connecting to devices, it may be advisable to divide discovery into several subsets of IP ranges.
     
  6. Click on Exit Setup.
  7. Click Refresh in the Privacy Manager software window.  As the software works through the IP addresses in the specified range, devices will become visible in the main software window.
  8. Once a device is visible, double-clicking on it allows the user to check its status and adjust levels.

Troubleshooting connections to a Dynasound system

If some or all of the Dynasound devices are not showing up in the Privacy Manager software, try the following:

  • Check to make sure that the computer has a good physical path to the CobraNet network.
  • Swap out Ethernet cables connecting the computer to the CobraNet network.
  • Verify that the computer's IP settings are within the same subnet as the Dynasound system.
  • Use an IP scanner to verify that the IP addresses for Dynasound are actively in use.
  • Open a Windows command prompt, type "arp -a", and hit Enter. This will list all IP addresses that the computer can detect on its network. If the computer is on the correct CobraNet network, the Dynasound device IP addresses should be listed.
  • If connecting directly to a DS3002 or DS3008's network port (i.e., not through a network switch), ensure that a crossover cable is being used.
  • Was this article helpful?