QtPro products quick comparison guide
This article offers a side by side comparison of the QtPro products currently available from Biamp. Consult the table below to review information on the number of emitters, zones, types of emitters, and other relevant details when considering how to design a space. At the bottom of the article, a link is provided for requesting a quote and more information on difficult to design areas.
QtPro comparison table
This table includes all five QtPro systems, outlined with their most commonly questioned differences. Note that the top row items are links to the available product page should you require more detailed specifications.
QtPro Patient Privacy (HCE) | Qt Conference Room Edition (CRE) | Qt 100 | Qt 300 | Qt 600 | |
Number of emitters supported |
8 Qt Emitters 60 Emitters per run x 2 runs (120 Total) |
8 Qt Emitters (included) 60 Emitters per run x 2 runs (120 Total) |
60 Emitters per run x 2 runs (120 Total) |
60 Emitters per run x 2 runs (120 Total) 50 Active Emitters per run x 2 runs (100 Total) |
60 Emitters per run x 2 runs (120 Total) 50 Active Emitters per run x 2 runs (100 Total) |
---|---|---|---|---|---|
Number of zones | 1 | 1 | 1 | 3 | 6 |
Number of runs | 2 per zone | 2 per zone | 2 per zone | 2 per zone, 6 total | 2 per zone, 12 total |
Types of emitter supported | Qt Emitters | Qt Emitters | Qt Emitters | ||
Analog inputs | 1 (stereo or mono) | 1 (stereo or mono) | 1 (stereo or mono) | 2 (stereo or mono) | 2 (stereo or mono) |
Privacy Signs | Yes - 2 Included | Yes - 2 Included | No | No | No |
Configuration options |
Front panel Contact Closure (On/Off) |
Front panel Contact Closure (On/Off) |
Front panel |
Front panel Internal webpage |
Front panel Internal webpage |
Masking noise level | 30 to 60 dBA @ 1 meter | 30 to 60 dBA @ 1 meter | 30 to 60 dBA @ 1 meter |
30 to 55 dBA @ 1 meter (Qt Emitter) 30 to 60 dBA @ 1 meter |
30 to 55 dBA @ 1 meter (Qt Emitter) 30 to 60dBA @ 1 meter |
Paging BGM level | Max 62 dBA @ 1 meter distance | Max 62 dBA @ 1 meter distance | Max 62 dBA @ 1 meter distance |
Max 57 dBA @ 1 meter (Qt Emitter) Max 74 dBA @ 1 meter |
Max 57 dBA @ 1 meter (Qt Emitter) Max 74 dBA @ 1 meter |
Works with SageVue? | No | No | No | Yes | Yes |
Key features |
|
|
|
|
|
Emitter types
This table shows the two available emitters and their differences. Note that the top row items are links to the product page should you require more detailed specifications.
Adjustable Emitters | Active Emitters (PoE assisted) | |
Height | 2.5” (6.4 cm) | 3.5” (8.9 cm) |
---|---|---|
Weight | 5.6 oz. (159 g) | 6.5 oz. (184g) |
Diameter | 3.25” (8.3 cm) | 3.25” (8.3 cm) |
Colors |
White available *Black cap included when ordered w/black SKU |
White and black are available *Cannot be painted |
Frequency response |
|
|
Max output |
|
|
Attenuation Steps (DIP Switch) | 0 dB (Default) , -3 dB, -6 dB, -9 dB | 0 dB (Default), -1.5 dB, -3 dB, -4.5 dB |
Wiring |
Plenum rated CAT3 / 8 Pair UTP / |
Plenum rated CAT3 / 8 Pair UTP / TIA-EIA 568B Termination |
Works with |
|
|
Requires PoE injectors? | No | Yes - link here, and here for power supply |
Masking curve (in control device) | Standard | Active or Standard Selectable |
Works with Qt RC? | Yes - Qt-RC2 only | Yes - Qt-RC3 only |
Emitter spacing guide
All QtPro lines use Qt Emitters. Follow these guides when outlining the space where sound masking is required
Ceiling / Mounting height | Emitter grid spacing |
---|---|
Less than 9' (2.7 m) | 8' x 8' (2.6 m x 2.6 m) |
9' to 12’ (2.7-3.6 m) | 10’ by 10’ (3 m x 3 m) |
12' & above (3.6 m +) | 12’ by 12’ (3.6 m x 3.6 m) |
For more information on laying out the emitters see our install guide here.
Emitter mounting options
All of the emitter mounting options listed will work for Qt adjustable and Active Emitters.
The data sheet for all mounting options can be found here
QT mounting accessory name | Picture | Instructions |
---|---|---|
Beam Bracket - for mounting to I-beams - White and black are available |
Mounting guidelines and instructions. See page 2 | |
Universal Bracket - For mounting externally to a wall or ceiling. - White and black are available. |
Mounting guidelines and instructions. See page 1 | |
Drywall mounting - for mounting into drywall ceilings. Roughin Bracket, as a wiring guide for installers (optional). |
Mounting guidelines and instructions. See page 3 | |
Ceiling Conduit Mount - for regions with special fire and/or conduit requirements.
|
Ceiling Conduit mounting instructions. | |
Pendant Mount - for ceilings higher than 22 ft, a pendant mount will be required to lower the emitter height. - White and black are available. |
Pendant Mount instructions. |
Further reading
- Cambridge Sound Management main website - for an overview on all sound masking products both Qt and Dynasound
- Quote request form - one of our design engineers can provide a layout & quote based on the information in this form.