LAN/Serial Sequence - Mute command
This sequence can be executed when control system is on.
RS232/RS485 byte delay: If you need a delay between each byte sent on the RS232/RS485 port you can specify that here. This setting will take effect for only this sequence. If you need the delay for all the sequences you can specify it in the settings for RS232/RS485. This is only an option for devices from version 2.00.
Always remember to fill in both the "Mute on" and "Mute off" commands.
Item |
Description |
The time between commands... |
Defines the time between sending the first command and the second command. If the second command are not in use, this time is discharged. |
The time from mute on... |
Here you define the time from the last command is sent, until the device is ready for the next command. |
The time from mute off... |
Here you define the time from the mute off command i sent, until the device is ready to receive the next command. |
The sequence has the following function:
When mute is off and mute key is pressed:
- The LED on the button start flashing.
- First Mute on command is sent.
- Wait "Time between commands..." (if second command is available).
- Second Mute on command is sent. (If available).
- Wait "The time from mute on..." and release keyboard.
- The LED on the button keep flashing.
When key is released again:
- Nothing.
When mute is on and mute key OR any other key is pressed (except for the buttons that only handle I/O operation):
- The LED on the button start flashing.
- The first Mute off command is sent.
- Wait "Time between commands..." (if second command is available).
- Second Mute off command is sent. (If available).
- Wait "The time from mute off..." and release keyboard.
- The LED on the button stop flashing.
When key is released again:
- Nothing.